Regarding performance indicators of fireproof and thermal insulation materials, absolute values are often used as statistical indicators. Still, such fundamental values are not convenient for judging the performance of products. Therefore, fire protection standards in various countries have emerged as the times require.
Through these standards, we can easily have a basic understanding of material properties. Let's look at Heaterk to understand the fire test standards of fire insulation materials in various countries.
1. China's fire test standards for building materials products
GB 12955—2015 Fire doors
GB 12441-2018 Decorative fire retardant coating
GB 14907-2018 Fire-retardant coatings for steel structures
GB 14102-2005 Fire shutter
GB 23864-2009 Fireproof sealing material
GB 15763.1-2009 Safety glass for construction - Part 1: Fireproof glass
GB/T 16809-2008 Steel fire windows
GA 304-2012 Plastic Pipe Firestop
2. China's fire test standards for building materials
GB 8624-2012 Classification of combustion performance of building materials and products
GB 20286-2006 Requirements and marking of flame retardant products and components in public places
GB/T 2408-2008 Test method for plastic combustion performance-horizontal and vertical combustion method
GB/T 8323.2-2008 Test method for combustion performance of plastics Test method for smoke density
GB T 7633-2008 Fire resistance test method for doors and shutters Standard
GBT 9978.1-2008 Test method for fire resistance of building components - Part 1 General requirements
GB/T 9978.4-2008 Test method for fire resistance of building elements - Part 4: Special conditions for load-bearing vertical partition elements
GB T 9978.5-2008 Test method for fire resistance of building components - Part 5: Special needs for load-bearing horizontal partition construction
GB T 9978.6-2008 Test method for fire resistance of building components - Part 6: Particular requirements for beams
GB T 9978.7-2008 Test method for fire resistance of building components - Part 7: Particular requirements for columns
GB T 9978.8-2008 Test methods for fire resistance of building elements - Part 8: Particular requirements for non-load-bearing vertical partition elements
GB T 9978.9-2008 Fire resistance test method for building components - Part 9: Special conditions for non-load-bearing ceiling components
GBT 5454-1997 Textile combustion performance test-oxygen index method
GB/T 5455-2014 Textiles - Combustion properties - Vertical direction - Determination of damage length smoldering and afterburning time
GB/T 5464-2010 Test method for non-combustibility of building materials
GB/T 7633-2008 Fire resistance test method for doors and shutters
GB/T 8333-2008 Test method for flammability of rigid foam plastics Vertical flammability
GB/T 8332-2008 Test method for combustion performance of foamed plastics Horizontal combustion method
GB/T 8625-2005 Test method for flame retardancy of building materials
GB/T 8626-2007 Test method for flammability of building materials
GB/T 8627-2007 Test method for smoke density of building materials
GB/T 11785-2005 Determination of Critical Radiation Flux of Flooring Materials - Radiant Heat Source Method
GB/T 14402-2007 Combustion performance of building materials and products-Test of calorific value of combustion
GB/T 20284-2006 Single Combustion Test of Building Materials or Products
GB/T 20285-2006 Material Smoke Toxicity Hazard Classification
GB 50222-2001 Technical code for fire protection of interior decoration of buildings
GB/T 11020-2005 List of methods for combustion characteristics of solid non-metallic materials exposed to flame sources
GB/T 11785-2005 Determination of Critical Radiation Flux of Flooring Materials Radiant Heat Source Method
GB/T 16172-2007 Test method for the heat release rate of building materials
GB/T 24573-2009 Test method for fire resistance of vault and archive doors
GB/T 12513-2006 Test method for fire resistance of glass-inlaid components
3. International fire test standards for building materials
ISO 834-1 - Fire resistance tests - Building elements - Part 1 General requirements
ISO5659-2 Optical Density Determination of Single Smoke Box
ISO11925-2 single ignition source flammability test
ISO1182 non-combustibility test of building materials
ISO 1716 Determination of Heat of Combustion
ISO9239-1 Flooring Materials - Radiant Heat Source Method
ISO5660-1 Heat Release Rate Test
ISO 5660-2 Burning tests - Heat release, smoke generation, and mass loss - Part 2 Dynamic determination of smoke
ISO 5658-2 Fire test for the lateral flame spread of building elements (international standard)
4. American fire test standards for building materials
ASTM E1354 Oxygen Consumption Method for Determination of Heat Release and Smoke Release Rates from Materials
ASTM E 970 Test Method for Critical Radiant Flux of Attic Floor Insulation Using Radiant Heat Energy Exposure
ASTM D3675 Test Method for Surface Burning of Flexible Porous Materials by Radiant Heat Source Method
ASTM E814 Test Method for Ignition Temperature of Penetration Fire Arresting Systems
ASTM E84 Surface Burning Properties of Building Materials
ASTM E119 Fire Testing of Building Materials
ASTM E136 Nonflammability Test
ASTM E162 Radiant Heat Source Surface Burning Performance Test
ASTM D3675 Fire Test for Surface Burning of Flexible Porous Materials with Radiant Heat Sources
ASTM E648 Critical Radiation Test for Floor Materials
ASTM D2843 Plastic Smoke Density Test
NFPA259 Building Materials Potential Heat Test
UL 723 Method for Determination of Surface Burning Properties of Building Materials
UL 263 Fire Testing of Building Structures and Materials
UL 10C Fire Tests for Fire Door Fittings
UL 10B Fire Test for Fire Door Fittings
UL 2043 Air Handling Separation Products and Their Accessories Fire Tests for Heat and Visible Smoke Release
5. EU fire test standards for building materials
EN13823 Single-body combustion test of building materials
EN 1363 Flame Resistance Test
EN 1364 Non-load bearing flame test
EN 1365 Load bearing flame resistance test
EN 13501-1 Determination of fire rating of building products
EN 13501-2-2007 Classification of fire resistance of building products and components in the European Union
EN 1634-1 Fire resistance testing of building materials - Part 1: Fire-rated doors and shutters
6. Canadian fire test standards for building materials
CAN/ULC-S127 Determination of flammability characteristics of non-melting foamed plastic building materials by the corner method
CAN/ULC-S114-05 Test method for non-combustibility of building materials
CAN/ULC-S102-10 Test Method for Surface Burning Characteristics of Building Materials and Fittings
CAN/ULC-S102-3 Method of Fire Test for Diffusers and Lenses of Luminaires
CAN/ULC-S102-2 Test method for building surface burning characteristics of floors, floor coverings, and other materials and accessories
CAN/ULC-S129 Insulation Resistance Smoldering Test Method
CANNULA-S135 Test Method for Determining Combustion Properties of Building Materials Using an Oxygen Consumption Calorimeter
7. Australian fire test standards for building materials
AS1530 Flame Retardant Fire Test of Building Materials
AS1530.4 Fire resistance test of building materials
AS/NZS 1530.2 Fire testing of building materials, elements, and members, part 2 Materials flammability testing
AS/NZS 1530.1 Fire testing of building materials, components, and members, Part 1 Material flammability testing
AS 1530.3 Building materials testing for flammability, flame spread, and heat release smoke performance
AS/NZS 3837 Oxygen Consumption Calorimeter Test Method for Heat Release and Smoke Generation of Materials and Products
8. British fire test standards for building materials
BS 5839-1 Building fire detection and alarm systems - Part 1: System design, installation, commissioning, and maintenance
BS 5803-3 Insulation of pitched roof spaces of dwellings - Specification for blown cellulose fiber insulation
BS 5803-2 Insulation of pitched roof spaces of dwellings - Part 2 Shot or granular artificial minerals applied by blowing
BS 476-3 Fire testing of building materials and components - Fire testing of exposed parts of roofs
BS 476-4 Non-combustibility testing of building materials
BS 476-5 Fire test for fire resistance of building materials and components - ignitability test
BS 476-6 Fire tests for fire resistance of building materials Fire tests on building materials and structures - Part 6: Test methods for the spread of flames in products
BS 476-7 Fire testing of building materials and systems - Part 7: Test methods for the determination of flame surface extension levels for products
BS 476-11 Method for determining thermal radiation of building materials
BS 476-15 Fire testing of building materials and structures - Test method for the heat release rate of products
BS 476-20 Fire resistance test for building materials
BS 476-21 Fire resistance testing of load-bearing materials
BS 476-22 Fire resistance test of non-load bearing parts of building materials
BS 476-23 Fire testing of building materials and components - Test method for the contribution of members to the fire resistance of components
BS 7955 Control nets and sheets for construction work - Specification for properties and test methods
ENV 1187 Fire Testing of Building Materials and Components - Fire Testing of Exposed Roofs
9. French fire test standards for building materials
NF P92-501 Building Materials Class M Fire Test
NF P92-503 Building Materials Class M Fire Test
NF P92-504 Combustion Flame Propagation Rate Test
NF P92-505 Burning Droplet Test
NF P92-507 M Grade Grading Standard
10. German fire test standards for building materials
DIN 4102-1 Fire performance class test for building materials